ASSOCIATED KEROSENE &  OIL LAMPS

AUSTRALIA

BRAIDWOOD

KEROSENE HEATERS

23/10/2017

            Home Page          Kerosene Heaters Parts

      CORONA  SX - B21   -  

       Portable Kerosene Heater  

     SAFETY SHUT-OFF VALVE  - IF HEATER TIPS

  •   Heating Output       2.09 kw
  •   Heating Area          Up to  20 m2
  •   Tank Capacity       3.0 Lt
  •   Heating Time         Approx 14 hours
  •    Ignition                   2 x D Batteries
  •    Size                       475 x452 x 314
  •    Weight  Empty       7.5 kg    

We are NO longer selling the heaters
they can be purchased at Stratco
we are still selling the Corona wicks

Corona Heater Wicks  -  $35.00

Bulk kerosene from the pump can be purchased at the Caltex Service Station, Garfield Road, Marsden Park information given by a customer a couple of years ago.

 

 

                                                                    __________________________________________________

GENERAL INSTRUCTIONS FOR KEROSENE HEATERS

 

ALWAYS PUT A NEW WICK INTO A SECOND- HAND HEATER

 

BEFORE PUTTING IN A NEW WICK

Small amounts of water can ruin a wick.  Water that is trapped in the wick will block the flow of kerosene.  This causes low, uneven flames and

          possibly odour.  Water condensation can occur in heater tank or storage tin.   See instructions below for storage after use. 

 

HEATER PROBLEMS

 IF YOUR HEATER HAS A BAD ODOUR

 
       

 CAUSE                                                                               SOLUT

 Heat chamber is tilted or improperly seated                                     Move wire handle

                            Wick is set too high                                    Reduce wick height by turning wick adjuster knob clockwise

            Dirty wick                                                           Dry clean (see below) or install a new wick

            Contaminated, old or poor quality kerosene                    Replace with fresh filtered kerosene.

            IF HEATER IS FLICKERING OR HAS  A LOW FLAME

            CAUSE                                                                               SOLUTION
  Dirty wick                                                                            Clean wick or put in a new one

            Water in fuel or poor quality kero                                          Drain tank, install new wick, refill with fresh filtered kerosene

            Wick is too low to sustain a good flame                                 Remove wick & install to correct height

           

 